Worked exampleSKL-000006

Floor beam

gkqkLRARB
Transparent stepsStandards-basedDocument as PDF

Choose a calculated example

Explore the saved results, then adapt the example to your project.

Results for the selected example

Floor beam

The results apply to these saved inputs. Changing the inputs requires a new calculation.

Open full calculation in CALC
System and inputs

System and input parameters

Read-only inputs for this calculation. Changes require a new calculation.

System

Structural system
Simply supported beam
Span L
6 m

Cross-section & material

Cross-section
IPE 300
Material
S235

Loads

Include beam self-weight
Yes
Permanent load gk
5 kN/m
Variable load qk
10 kN/m
Point load
No

Verification

Lateral restraint of the compression flange
Continuously restrained
National Annex
DE – DIN EN 1993-1-1/NA
Deflection limit
L/250 total

Result diagrams

IPE 300 · S235 · L = 6.00 m · qd = 22.3 kN/m

  • Maximum moment100.4 kNm
    Mmax = 100.4 kNmx = 3.00 m
  • Maximum shear66.9 kN
    Vmax = 66.9 kNx = 0.00 m
  • Elastic deflection14.8 mm
    |u|max = 14.8 mmx = 3.00 m

Verification overview

IPE 300 · S235 · L = 6.00 m · qEd = 22.31 kN/m

Governing check: Bendingη = 0.68Passed32% margin to limit
Limit η ≤ 1.00

Calculated on · Skill version 0.8.1

Prepare your calculation
Dlubal CALC
Configure your beam
Structural calculation to standard

System sketch

L = 6 mgk = 5 kN/mqk = 10 kN/m
Show calculation flow

m
All required fields completed

Inputs completeReady to calculate

What this skill checks

Ultimate limit state

Check bending, shear, their interaction, and the governing utilisation to EN 1993-1-1.

Serviceability

Calculate deflection and compare it with the agreed project or National Annex limit.

Lateral-torsional buckling

Assess member stability using the unrestrained length, moment shape, and support conditions.

Vibration screening

Estimate the first natural frequency as a serviceability hint, not a code verification.

Frequently asked questions

Which inputs does Mia need for the design?

At minimum, provide the static system, span, section, steel grade, loads, and lateral restraint. Mia asks targeted questions when a governing input is missing.

Is lateral-torsional buckling considered automatically?

Yes, when the compression flange is not continuously restrained and the unrestrained length and support conditions are known.

Which deflection limit is used?

The project or National Annex limit takes precedence. If none is given, Mia names the customary default used and flags it as an assumption.

Can I document the calculation?

CALC presents inputs, assumptions, checks, the governing utilisation, and normative references in a structured answer that can be exported as a PDF.

Ready for your first check?

Start with the example and adapt it to your structural system.

New calculation