Privacy settings

We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000079 · Skill

EN 1992-1-1:2004+AC:2010, 8.4 to 8.7DIN EN 1992-1-1/NA:2013-04+A1:2015-12UK NA to BS EN 1992-1-1:2004 (NA+A2:2014)

Anchorage and lap lengths of reinforcing bars to Eurocode 2 and ACI 318

Enter the code edition, the bar, the concrete strength, the bond or casting position, and the detailing values. Mia calculates the anchorage length lbd or the lap length l0 to EN 1992-1-1, or the development length ld or ldc and the lap splice length lst or lsc to ACI 318, with every factor and its clause. With a provided length, the utilization η = l,req / l,prov (required length / provided length) is checked.

Mia

Mia guides you step by stepShe guides you through the inputs and explains the results.

Worked example

Lap of φ 16 mm bars | C30/37 | German NA

Lap length fulfilled
Lap of φ 16 mm bars | C30/37 | German NA
Code
EN 1992-1-1, German National Annex
Bar
φ = 16 mm, fyk = 500 MPa, straight
Concrete
C30/37, good bond
Lap
ρ1 = 100 %, a < 8φ, l,prov = 1200 mm

Check the lap length of B500 bars, φ = 16 mm, in C30/37 to EN 1992-1-1:2004+AC:2010 with DIN EN 1992-1-1/NA:2013-04+A1:2015-12. Tension, good bond, straight bars, cd = 30 mm, all bars lapped in one section, clear distance of the laps below 8φ, provided lap length l,prov = 1200 mm.

Key results

Basic required anchorage length lb,rqd
571.8 mm
Lap factor α6 (Table 8.3DE)
2.0
Lap length l0
1143.7 mm (detailing 1145 mm)
Utilization η = l0 / l,prov
0.95

Deterministic values of the calculation code for the stated inputs; l0,min = 343.1 mm does not govern.

  • — fbd = 3.04 MPa with fctk,0.05 from the Table 3.1 formula and αct = 1.0.
  • — α1 = α3 = α5 = 1.0 without further detailing data.

Required inputs

  • Code edition and, for EN 1992-1-1, the National Annex
  • Check: anchorage length or development length, or lap length; tension or compression
  • Bar diameter φ and fyk, or ACI bar size and grade
  • Concrete strength fck or f'c, and lightweight concrete for ACI 318
  • Bond condition (EN) or top bar and coating (ACI)
  • Detailing values such as cd, bar end, ρ1, the spacing and cover case, and the splice class

What you receive

  • Required length lbd, l0, ld, ldc, lst, or lsc in mm, for ACI 318 also in in.
  • Utilization η = l,req / l,prov when a provided length is given
  • Basic values fbd and lb,rqd, or the development length ld before the minimum length
  • Every modification factor α or ψ with its clause
  • Minimum lengths lb,min, l0,min, or the ACI minimum length
  • Notes on detailing conditions and conservative defaults

Start from an input template

These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.

Prepare your calculation
Dlubal CALC
Anchorage and lap length | code, bar, concrete, and provided length
Structural calculation to standard

System sketch

All required fields completed

Inputs completeReady to calculate

What this skill checks

Four rule sets

EN 1992-1-1:2004+AC:2010 with the recommended values, the German National Annex DIN EN 1992-1-1/NA:2013-04+A1:2015-12, or the UK National Annex NA+A2:2014, and ACI 318-19 or ACI 318-25.

Eurocode 2 anchorage and laps

fbd, lb,rqd, the factors α1 to α6, lb,min and l0,min to 8.4 to 8.7, with α6 from Table 8.3DE and the As,req/As,prov factor of the German National Annex.

ACI 318 development lengths and lap splices

Development length ld by Table 25.4.2.3 or Eq. (25.4.2.4a) with ψt, ψe, ψs, ψg, and λ, development length ldc in compression, and lap splice lengths lst (Class A or B) and lsc to 25.5.

Check of a provided length

With a provided length l,prov, the utilization η = l,req / l,prov is reported and the check is fulfilled at η ≤ 1.00.

Ready for your first check?

Start with the example and adapt it to your structural system.

New calculation