EN 1992-1-1:2004+AC:2010, 8.4 to 8.7DIN EN 1992-1-1/NA:2013-04+A1:2015-12UK NA to BS EN 1992-1-1:2004 (NA+A2:2014)Enter the code edition, the bar, the concrete strength, the bond or casting position, and the detailing values. Mia calculates the anchorage length lbd or the lap length l0 to EN 1992-1-1, or the development length ld or ldc and the lap splice length lst or lsc to ACI 318, with every factor and its clause. With a provided length, the utilization η = l,req / l,prov (required length / provided length) is checked.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Check the lap length of B500 bars, φ = 16 mm, in C30/37 to EN 1992-1-1:2004+AC:2010 with DIN EN 1992-1-1/NA:2013-04+A1:2015-12. Tension, good bond, straight bars, cd = 30 mm, all bars lapped in one section, clear distance of the laps below 8φ, provided lap length l,prov = 1200 mm.
Deterministic values of the calculation code for the stated inputs; l0,min = 343.1 mm does not govern.
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
EN 1992-1-1:2004+AC:2010 with the recommended values, the German National Annex DIN EN 1992-1-1/NA:2013-04+A1:2015-12, or the UK National Annex NA+A2:2014, and ACI 318-19 or ACI 318-25.
fbd, lb,rqd, the factors α1 to α6, lb,min and l0,min to 8.4 to 8.7, with α6 from Table 8.3DE and the As,req/As,prov factor of the German National Annex.
Development length ld by Table 25.4.2.3 or Eq. (25.4.2.4a) with ψt, ψe, ψs, ψg, and λ, development length ldc in compression, and lap splice lengths lst (Class A or B) and lsc to 25.5.
With a provided length l,prov, the utilization η = l,req / l,prov is reported and the check is fulfilled at η ≤ 1.00.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: DIN EN 1992-1-1:2011-01 (EN 1992-1-1:2004 + AC:2010) + DIN EN 1992-1-1/A1:2015-03
| Country | National Annex | Factors | Source |
|---|---|---|---|
| EN | Recommended valuesEN 1992-1-1:2004 + AC:2010 | γC = 1.50γS = 1.15αct = 1.00 | – |
| DE | DIN EN 1992-1-1/NA:2013-04 + DIN EN 1992-1-1/NA/A1:2015-12Current | γC = 1.50γS = 1.15αct = 1.00 | DIN Media |
| GB | NA+A2:2014 to BS EN 1992-1-1:2004+A1:2014 | γC = 1.50γS = 1.15αct = 1.00 | – |
Status checked on
Edition used: ACI CODE-318-25 (2025)
Status checked on
Edition used: ACI 318-19 (2019, errata 2021)
Status checked on
Frequently asked questions
EN 1992-1-1:2004+AC:2010 with the recommended values, with DIN EN 1992-1-1/NA:2013-04+A1:2015-12, or with the UK National Annex NA+A2:2014, and ACI 318-19 and ACI 318-25. Other editions are refused with the list of supported ones; Mia never substitutes another edition.
Optional values take conservative defaults, for example cd = 0, ρ1 = 100 %, As,req/As,prov = 1.0, and fyk = 500 MPa, and every default is named in the answer. Without a provided length, only the required length is calculated.
An automated test recomputes published worked examples of The Concrete Centre, the JRC Eurocode 2 workshop, and Structville for the recommended values, ISB Arbeitsblatt 7 for the German National Annex, and the Dayton Superior Rebar Splicing Handbook for ACI 318.
The German National Annex takes α6 from Table 8.3DE, which depends on the bar diameter, the share of lapped bars, and the spacing of the laps, and it sets α2 = 1.0. For φ ≥ 16 mm with more than 33 % lapped bars and a clear distance below 8φ, α6 = 2.0.
No. Standard hooks (25.4.3) and headed bars (25.4.4) are out of scope. For EN 1992-1-1, bends, hooks, and loops are covered through α1.
Start with the example and adapt it to your structural system.