EN 1992-1-1:2004+AC:2010 with the recommended values or with DIN EN 1992-1-1/NA, including the lever arm limit of the NCI to section 6.2.3(1) in the German path.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000134 · Skill
EN 1992-1-1:2004+AC:2010+A1:2014, 3.1.7, 6.1, 6.2.2, 6.2.3, 6.5.3, 8.4, 9.2.2DIN EN 1992-1-1/NA:2013-04 + NA/A1:2015-12, NDP to 6.2.2(1), 6.2.3(2), 6.2.3(3), 8.4.4(1), 9.2.2(5) to (8)DAfStb Heft 599 (2013), chapter 4, Eq. (4.1) to (4.10), Table 4-1Enter the National Annex, the beam section, the opening size and position, the concrete and steel, and the internal forces at the opening center. Mia splits the forces to the top and bottom chord with the frame model of DAfStb Heft 599, designs the chords, the chord stirrups, and the hanger reinforcement on both sides, and reports the governing utilization with the clause named.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Check a rectangular web opening in a reinforced concrete beam to DIN EN 1992-1-1 with the German National Annex: h = 700 mm, bw = 300 mm, opening 400 x 250 mm, 200 mm above the soffit, 1500 mm from the support face, C30/37, B500B, MEd = 180 kNm, VEd = 140 kN at the opening center.
Values from the calculation code of the skill for the stated inputs with the provided reinforcement As_o1 = As_o2 = As_u2 = 226 mm², As_u1 = 942 mm², asw_o = 1257 mm²/m, asw_u = 628 mm²/m, and hangers 628 / 314 mm². All ten checks are satisfied.
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
EN 1992-1-1:2004+AC:2010 with the recommended values or with DIN EN 1992-1-1/NA, including the lever arm limit of the NCI to section 6.2.3(1) in the German path.
The shear is split to the chords by stiffness, and each chord is designed for its axial force, bending moment, and shear to sections 6.1 and 6.2, as in DAfStb Heft 599, chapter 4.
Large openings with the frame model and small openings with a continuous truss, in rectangular beams and T-beams; a circular opening is designed with an equivalent square.
Hanger reinforcement on the span and support side, additional longitudinal bars with their anchorage to section 8.4, and detailing notes for the corner bars.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: EN 1992-1-1:2004 + AC:2010
| Country | National Annex | Factors | Source |
|---|---|---|---|
| DE | DIN EN 1992-1-1/NA:2013-04 + DIN EN 1992-1-1/NA/A1:2015-12Current | γC = 1.50γS = 1.15αcc = 0.85 | DIN Media |
Status checked on
Frequently asked questions
EN 1992-1-1:2004+AC:2010 (+A1:2014) with the recommended values or with the German National Annex DIN EN 1992-1-1/NA:2013-04 + NA/A1:2015-12. EN 1992-1-1:2023 and other National Annexes are refused.
The two worked examples of DAfStb Heft 599, 4.4.2 (large opening in the span) and 4.4.3 (large opening near the support), are recomputed by an automated test; all 42 published values lie within the tolerances.
The frame model for large openings always applies. The small-opening path uses a continuous truss and is only possible when the truss can form (ha at most z/3, la at most the maximum stirrup spacing); otherwise the skill recommends the large-opening design. The small-opening path is self-derived from DAfStb Heft 599, 4.2 and marked so in the result.
A circular opening is replaced by an equivalent square opening, a secondary rule that the result names in its notes.
Start with the example and adapt it to your structural system.