We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.
EN 1995-1-1:2004+A2:2014, 6.4.2EN 1995-1-1:2004+A2:2014, 6.4.3EN 1990, 6.4.3
Design pitched cambered timber beams to Eurocode 5
Describe the geometry (including any cantilevers), material, and internal forces at each section. Mia runs the full EN 1995-1-1 verification suite: shear, combined tension/compression and bending, ridge bending and tension perpendicular to grain, lateral-torsional buckling, and support pressure, with the governing utilisation named.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Worked example
GL24c pitched cambered beam, hap 1.00 m, R 20 m, with cantilevers
Material
GL24c glulam per EN 14080
Apex height hap
1.00 m
Curvature radius R
20 m (inside face)
Cantilevers
1.5 m each end
Verify the apex zone of a pitched cambered glulam beam GL24c, b = 250 mm, hap = 1.00 m, R = 20 m (to the inside face), delta = 15 degrees, t = 40 mm, service class 2, gamma_M = 1.3, apex zone volume V = 2.68 m3, Map,d = 143.7 kNm.
•Geometry: span l, support widths la/l_b, beam width b, upper/lower edge slope angles, beam heights (hs,ha,hFirst,hap), curvature radius R and its reference face; optional cantilever length/end slope/bottom-edge slope on either end
•Glulam strength class (or fm,k / ft,0,k / ft,90,k / fc,0,k / fc,90,k / fv,k), lamination thickness t, E0,05 and G0,05 for lateral-torsional buckling
•Service class, load-duration class(es), gamma_M, and the shear crack factor kcr per your National Annex
•For the ridge check: Map,d directly, or roof loads (permanent/snow/wind) plus a tributary width for a symmetric span case
•For every other check (shear, tension/compression+bending, tapered-edge bending, lateral-torsional buckling, support pressure): Nd,Vd,Md at that section, from your own analysis (e.g. an RFEM model). This skill does not perform frame/arch analysis itself
What you receive
•Utilisation ratio and governing EN 1995-1-1 clause for every check run
•The governing check named across the whole beam
•Deflection results against the applicable National Annex limits
Start from an input template
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Apex bending and tension-perpendicular interaction (6.4.3)
Checks the ridge-zone bending stress (k_l) and the combined tension-perpendicular-to-grain/shear interaction (k_dis, k_vol). The apex angle alpha_ap is taken as the true local edge slope at the apex (0 for a smoothly curved ridge, not the support-end taper angle), matching verified RX-TIMBER output.
General section checks (6.1.7, 6.2.2-6.2.4, 6.4.2)
Shear (with the crack-reduction factor), combined tension/compression and bending at any section including cantilevers, and bending on straight tapered edges (tension and compression side).
Lateral-torsional buckling (6.3.3)
Computes the relative slenderness and k_crit from the critical bending stress, given the section's lateral and torsional stiffness and effective buckling length.
Support pressure at an angle (6.2.2)
Checks compression at an angle to the grain at raked supports, with the effective contact length and k_c,90.
Deflection (Table 7.2)
Instantaneous, net-final (creep-adjusted), and combined characteristic/quasi-permanent deflection at midspan and at any cantilever tip, against the National Annex limits.
Normative basis
Standards & references
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
EN 1995-1-1
Eurocode 5: Design of timber structures – Part 1-1: General – Common rules and rules for buildings
Edition used: DIN EN 1995-1-1:2010-12 (EN 1995-1-1:2004 + AC:2006 + A1:2008) + DIN EN 1995-1-1/A2:2014-07
Withdrawn
§6.4.2
§6.4.3
DIN MediaNewer edition: DIN EN 1995-1-1:2026-09 (EN 1995-1-1:2025)
Full geometry (including any cantilevers), the glulam strength class and elastic properties, service/load-duration classes, and the internal forces (N,d, V,d, M,d) at each section you want checked. For the ridge check alone, roof loads plus a tributary width can stand in for a directly given Map,d.
ScopeDoes this replace a full structural analysis?
No. This skill checks stresses and capacities at sections you specify. For a curved or cantilevered beam under wind, deriving the internal forces at every section generally needs a real 2D/frame analysis (e.g. an RFEM model, skill 000005-rfem-model-design). Only the simple symmetric-UDL ridge moment can be derived by hand statics here.
VerificationWhy is alpha_ap not just the roof pitch angle?
For a beam whose top and bottom edges are both curved (a smoothly rounded ridge, not a sharp angular apex), the edge slope AT the apex itself is 0 regardless of the overall roof pitch measured at the supports. Using the support-end slope there would overstate the apex bending check. Tell Mia explicitly if your beam instead has a straight tapered top maintained to a sharp ridge line.
ScopeCan this check a beam with cantilevers?
Yes. Describe the cantilever length, end slope, and bottom-edge slope on either side; the same section checks apply at cantilever locations, including the cantilever-specific deflection limits.
Question not answered?Ask Mia directly in CALC. She answers for this skill and your inputs.Ask Mia