Design vertical resistance of a masonry wall under a concentrated load: NRdc = β · Ab · fd.

NRdc=β⋅Ab⋅fd\displaystyle N_{Rdc} = \beta \cdot A_{\mathrm{b}} \cdot f_{\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NRdcAbfdβ

Formula and quantities

SymbolNameUnitNote
β\displaystyle βConcentrated load enhancement factor–β\displaystyle β ≥ 1, ≤ 1.5
Ab\displaystyle A_{\mathrm{b}}Loaded bearing areamm²Ab\displaystyle A_{\mathrm{b}} > 0
fd\displaystyle f_{\mathrm{d}}Design compressive strength of masonryN/mm²fd\displaystyle f_{\mathrm{d}} > 0
NRdc\displaystyle N_{Rdc}Design concentrated load resistancekNResult

Worked example

β\displaystyle β = 1.35 · Ab\displaystyle A_{\mathrm{b}} = 48,000 mm² · fd\displaystyle f_{\mathrm{d}} = 3 N/mm²

NRdc\displaystyle N_{Rdc} = 194.4 kN · Source: hand calculation

Scope and standard

EN 1996-1-1, clause 6.1.3.

Standard
EN 1996-1-1-2005-a1:2012, clause 6.1.3, Eq. (6.9)
Result
NRdc\displaystyle N_{Rdc} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRdc\displaystyle N_{Rdc} = 194.4 kN= 1.35 · (48,000 mm²) · (3 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Masonry.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.