Design · Masonry
Design vertical load resistance of masonry wall or pier
Total design vertical resistance of an unreinforced masonry wall or pier of length b and thickness t: NRd = Φ · b · t · fd.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Capacity reduction factor | – | ≥ 0, ≤ 1 | |
| Length of wall or pier | mm | > 0 | |
| Thickness of wall or pier | mm | > 0 | |
| Design compressive strength of masonry | N/mm² | > 0 | |
| Design vertical resistance | kN | Result |
Worked example
= 0.7 · = 1,000 mm · = 240 mm · = 2.5 N/mm²
= 420 kN · Source: hand calculation
Scope and standard
EN 1996-1-1, clause 6.1.2.1.
- Standard
- EN 1996-1-1-2005-a1:2012, clause 6.1.2.1, Eq. (6.2)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.