Design · Masonry
Design shear resistance of masonry wall
Design shear resistance of an unreinforced masonry wall over the compressed wall length: VRd = fvd · t · lc.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design shear strength of masonry | N/mm² | ≥ 0 | |
| Thickness of wall | mm | > 0 | |
| Length of compressed part of wall | mm | > 0 | |
| Design shear resistance | kN | Result |
Worked example
= 0.35 N/mm² · = 240 mm · = 2,500 mm
= 210 kN · Source: hand calculation
Scope and standard
Unreinforced masonry walls subject to in-plane shear according to EN 1996-1-1, clause 6.2.
- Standard
- EN 1996-1-1-2005-a1:2012, clause 6.2, Eq. (6.13)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Masonry.
Miaknows the formula catalog and asks for what is missing.