设计 · 砌体
砌体局部受压承载力设计值
局部荷载作用下砌体墙的竖向承载力设计值:NRdc = β · Ab · fd。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 局部受压提高系数 | – | ≥ 1, ≤ 1.5 | |
| 局部受压面积 | mm² | > 0 | |
| 砌体抗压强度设计值 | N/mm² | > 0 | |
| 局部受压承载力设计值 | kN | Result |
实例
= 1.35 · = 48,000 mm² · = 3 N/mm²
= 194.4 kN · Source: 手算
Scope and standard
EN 1996-1-1 第 6.1.3 条。
- Standard
- EN 1996-1-1-2005-a1:2012,第6.1.3条,式(6.9)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 砌体 开始。
Miaknows the formula catalog and asks for what is missing.