Design · Masonry

Design out-of-plane moment of resistance of masonry wall

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Design moment of resistance per unit width of an unreinforced masonry wall subject to lateral loading: MRd = fxd · t² / 6.

MRd=fxd⋅t26\displaystyle M_{\mathrm{Rd}} = f_{xd} \cdot \frac{t^2}{6}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

tMRd

Formula and quantities

SymbolNameUnitNote
fxd\displaystyle f_{xd}Design flexural strength of masonryN/mm²fxd\displaystyle f_{xd} ≥ 0
t\displaystyle tThickness of wallmmt\displaystyle t > 0
MRd\displaystyle M_{\mathrm{Rd}}Design moment resistance per unit widthNResult

Worked example

fxd\displaystyle f_{xd} = 0.25 N/mm² · t\displaystyle t = 240 mm

MRd\displaystyle M_{\mathrm{Rd}} = 2,400 N · Source: hand calculation

Scope and standard

EN 1996-1-1, clause 6.3.1.

Standard
EN 1996-1-1-2005-a1:2012, clause 6.3.1, Eq. (6.15)
Result
MRd\displaystyle M_{\mathrm{Rd}} in kN*m/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
MRd\displaystyle M_{\mathrm{Rd}} = 2,400 N= (0.25 N/mm²) · (240 mm) ^ 2 / 6

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Masonry.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.