집중하중을 받는 조적벽의 설계 수직 저항력: NRdc = β · Ab · fd.

NRdc=β⋅Ab⋅fd\displaystyle N_{Rdc} = \beta \cdot A_{\mathrm{b}} \cdot f_{\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NRdcAbfdβ

Formula and quantities

SymbolNameUnitNote
β\displaystyle β집중하중 증대계수–β\displaystyle β ≥ 1, ≤ 1.5
Ab\displaystyle A_{\mathrm{b}}재하 지압 면적mm²Ab\displaystyle A_{\mathrm{b}} > 0
fd\displaystyle f_{\mathrm{d}}조적조 설계 압축강도N/mm²fd\displaystyle f_{\mathrm{d}} > 0
NRdc\displaystyle N_{Rdc}집중하중에 대한 설계 저항력kNResult

예제

β\displaystyle β = 1.35 · Ab\displaystyle A_{\mathrm{b}} = 48,000 mm² · fd\displaystyle f_{\mathrm{d}} = 3 N/mm²

NRdc\displaystyle N_{Rdc} = 194.4 kN · Source: 수기 계산

Scope and standard

EN 1996-1-1 조항 6.1.3.

Standard
EN 1996-1-1-2005-a1:2012, 6.1.3 절, 식 (6.9)
Result
NRdc\displaystyle N_{Rdc} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRdc\displaystyle N_{Rdc} = 194.4 kN= 1.35 · (48,000 mm²) · (3 N/mm²)