Design · Masonry

Enhancement factor for concentrated loads on masonry

  • Type: Coefficient
  • Version 1
  • reviewed on 11/13/2026

Enhancement factor beta for concentrated bearing loads on masonry walls (Group 1 units): β = min((1 + 0.3 · a1 / hc) · (1.5 - 1.1 · Ab / Aef), 1.25 + a1 / (2 · hc), 1.5), >= 1.0.

β=max⁡(1.0, min⁡((1+0.3a1hc)(1.5−1.1AbAef), 1.25+a12hc, 1.5))\displaystyle \beta = \max\left(1.0,\, \min\left(\left(1 + 0.3\frac{a_{1}}{h_{\mathrm{c}}}\right)\left(1.5 - 1.1\frac{A_{\mathrm{b}}}{A_{\mathrm{ef}}}\right),\, 1.25 + \frac{a_{1}}{2h_{\mathrm{c}}},\, 1.5\right)\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Abhcβ

Formula and quantities

SymbolNameUnitNote
a1\displaystyle a_{1}Distance from end of wall to nearest edge of loaded areamma1\displaystyle a_{1} ≥ 0
hc\displaystyle h_{\mathrm{c}}Height of wall to level of loadmmhc\displaystyle h_{\mathrm{c}} > 0
Ab\displaystyle A_{\mathrm{b}}Loaded bearing areamm²Ab\displaystyle A_{\mathrm{b}} > 0
Aef\displaystyle A_{\mathrm{ef}}Effective area of bearing at mid-heightmm²Aef\displaystyle A_{\mathrm{ef}} > 0
β\displaystyle βConcentrated load enhancement factor–Result

Valid ifAb≤Aef\displaystyle A_{\mathrm{b}} \le A_{\mathrm{ef}}

Worked example

a1\displaystyle a_{1} = 600 mm · hc\displaystyle h_{\mathrm{c}} = 2,800 mm · Ab\displaystyle A_{\mathrm{b}} = 48,000 mm² · Aef\displaystyle A_{\mathrm{ef}} = 240,000 mm²

β\displaystyle β = 1.35714 · Source: hand calculation

Scope and standard

Group 1 masonry units under concentrated loads according to EN 1996-1-1, clause 6.1.3.

Standard
EN 1996-1-1-2005-a1:2012, clause 6.1.3, Eq. (6.10)
Result
β\displaystyle β (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
β\displaystyle β = 1.35714= max(1.0; min((1 + 0.3 · (600 mm) / (2,800 mm)) · (1.5 - 1.1 · (48,000 mm²) / (240,000 mm²)); 1.25 + (600 mm) / (2 · (2,800 mm)); 1.5))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Masonry.

Miaknows the formula catalog and asks for what is missing.