设计 · 砌体
砌体墙或壁柱受压承载力设计值
长度为 b、厚度为 t 的无筋砌体墙或壁柱的总竖向承载力设计值:NRd = Φ · b · t · fd。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 承载力折减系数 | – | ≥ 0, ≤ 1 | |
| 墙体或壁柱长度 | mm | > 0 | |
| 墙体或壁柱厚度 | mm | > 0 | |
| 砌体抗压强度设计值 | N/mm² | > 0 | |
| 竖向承载力设计值 | kN | Result |
实例
= 0.7 · = 1,000 mm · = 240 mm · = 2.5 N/mm²
= 420 kN · Source: 手算
Scope and standard
EN 1996-1-1 第 6.1.2.1 条。
- Standard
- EN 1996-1-1-2005-a1:2012,第6.1.2.1条,式(6.2)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 砌体 开始。
Miaknows the formula catalog and asks for what is missing.