Design · Concrete

Constant bond stress for prestress transfer fbpt (EN 1992-1-1)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Constant bond stress over the transmission length for pre-tensioned tendons according to EN 1992-1-1 Clause 8.10.2.2(1) Eq. (8.15): fbpt = ηp1 · η1 · fctd,t.

fbpt=ηp1⋅η1⋅fctd,t\displaystyle f_{bpt} = \eta _{p1} \cdot \eta _{1} \cdot f_{ctd,t}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fbpt

Formula and quantities

SymbolNameUnitNote
ηp1\displaystyle \eta_{p1}Tendon type bond coefficient (2.7 indented wires, 3.2 strands)1
η1\displaystyle \eta_{1}Bond condition coefficient (1.0 good, 0.7 other)1
fctd,t\displaystyle f_{ctd,t}Design concrete tensile strength at time of prestress releaseN/m²
fbpt\displaystyle f_{bpt}Constant transfer bond stressN/m²Result

Worked example

ηp1\displaystyle \eta_{p1} = 3.2 · η1\displaystyle \eta_{1} = 1 · fctd,t\displaystyle f_{ctd,t} = 1,800,000 N/m²

fbpt\displaystyle f_{bpt} = 5,760,000 N/m²

Standard and source

Result
fbpt\displaystyle f_{bpt} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fbpt\displaystyle f_{bpt} = 5,760,000 N/m²= (3.2 1) · (1 1) · (1,800,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.