Design · Concrete

Concrete modulus of rupture fr (ACI 318)

  • Type: Property
  • Version 1
  • reviewed on 11/15/2026

Modulus of rupture of concrete for deflection and cracking moment calculations according to ACI 318-19 Section 19.2.3.1 (SI): fr = 0.62 · λ · √(fc / MPa) · MPa.

fr=0.62⋅λ⋅fc′\displaystyle f_{r} = 0.62 \cdot \lambda \cdot \sqrt{f'_{\mathrm{c}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fc

Formula and quantities

SymbolNameUnitNote
λ\displaystyle \lambdaLightweight concrete modification factor (1.0 normalweight)1
fc\displaystyle f_{\mathrm{c}}Specified compressive strength of concreteN/m²
fr\displaystyle f_{r}Modulus of ruptureN/m²Result

Worked example

λ\displaystyle \lambda = 1 1 · fc\displaystyle f_{\mathrm{c}} = 28,000,000 N/m²

fr\displaystyle f_{r} = 3,280,700 N/m²

Standard and source

Standard
ACI 318-19
Result
fr\displaystyle f_{r} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fr\displaystyle f_{r} = 3,280,730 N/m²= 0.62 · (1 1) · sqrt((28,000,000 N/m²) / [MPa]) · [MPa]