Design · Concrete
Corbel primary tie design tensile force Ftd
Design tensile force in the primary tie of a reinforced concrete corbel to EN 1992-1-1 Annex J Eq. (J.2).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Vertical design load applied to the corbel | kN | ||
| Cotangent of the angle theta of the compressive strut (cot(theta) = (a_c + 0.2*a_1) / z_0) | 1 | ||
| Horizontal design force acting on the corbel (H_Ed >= 0.2 * F_Ed) | kN | ||
| Design tensile force in primary tie | kN | Result |
Worked example
= 300 kN · = 0.85 1 · = 60 kN
= 315 kN · Source: EN 1992-1-1:2004 Eq. (J.2)
Scope and standard
Short cantilevers and corbels to EN 1992-1-1 Annex J.
- Standard
- EN 1992-1-1:2004, clause J.3, Eq. (J.2)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.