Design · Concrete

Anchorage wedge draw-in influence length lw (EN 1992-1-1)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Length along a post-tensioned tendon affected by anchorage wedge draw-in slip assuming constant friction gradient according to EN 1992-1-1 Clause 5.10.5.3: lw = √(Δl · Ep · Ap / pfr).

lw=Δl⋅Ep⋅Appfr\displaystyle l_{w} = \sqrt{\frac{\Delta l \cdot E_{p} \cdot A_{p}}{p_{fr}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

lwApEp

Formula and quantities

SymbolNameUnitNote
Δl\displaystyle \Delta lAnchorage wedge draw-in slipmm
Ep\displaystyle E_{p}Modulus of elasticity of prestressing steelN/m²
Ap\displaystyle A_{p}Cross-sectional area of prestressing tendonmm²
pfr\displaystyle p_{fr}Friction force gradient per unit tendon lengthkN/m
lw\displaystyle l_{w}Wedge draw-in influence lengthmmResult

Worked example

Δl\displaystyle \Delta l = 6 mm · Ep\displaystyle E_{p} = 195,000,000,000 N/m² · Ap\displaystyle A_{p} = 1,800 mm² · pfr\displaystyle p_{fr} = 12 kN/m

lw\displaystyle l_{w} = 13,247.6 mm

Standard and source

Result
lw\displaystyle l_{w} in m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
lw\displaystyle l_{w} = 13,247.6 mm= sqrt((6 mm) · (195,000,000,000 N/m²) · (1,800 mm²) / (12 kN/m))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.