Two editions
ACI CODE-318-25 with its mechanism table and ACI 318-19 with the hand-off to shear friction, in US customary or SI units.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000142 · Skill
ACI CODE-318-25, 16.4, 22.9, 21.2.1, 20.2.2.4, Appendix EACI 318-19, 16.4, 22.9, 21.2.1, 20.2.2.4ACI 318M-19, 16.4, 22.9Enter the factored shear, the contact width, the depth, the concrete strength, the surface preparation, and the ties across the interface. Mia checks every permitted transfer mechanism of ACI 318 section 16.4, including shear friction to section 22.9, and reports the governing utilization, the tie spacing check, and the required ties.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Check the horizontal shear of a prestressed precast beam with a 4 in topping to ACI CODE-318-25: Vu = 60 kips, bv = 12 in, composite height h = 30 in, f'c = 5000 psi, two-legged #4 ties (Av = 0.40 in²) at 12 in, fyt = 60 000 psi, intentionally roughened surface.
Calculate the example with MiaThese templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
ACI CODE-318-25 with its mechanism table and ACI 318-19 with the hand-off to shear friction, in US customary or SI units.
Cementitious bond, the tie equation, and shear friction with A_c = b_v d are evaluated, and the largest permitted strength governs.
Minimum tie area to section 16.4.6.1 and the spacing limit to section 16.4.7.2 are checked with the clause named.
When the check fails, the smallest tie area per foot or per meter that satisfies the check is given, or the reason why more ties cannot help.
Normative basis
The checks follow these standards. Nationally determined parameters come from the National Annex selected in the form.
Edition used: ACI CODE-318-25 (2025)
Status checked on
Edition used: ACI 318-19 (2019, errata 2021)
Status checked on
Frequently asked questions
ACI CODE-318-25 and ACI 318-19, each in US customary or SI units. Older editions are refused, and Eurocode joints are checked with skill 000077-concrete-interface-shear-design.
Every formula was checked against the text of ACI 318-19, ACI 318M-19, and ACI CODE-318-25. Published and reference shear friction examples and hand calculations are recomputed by an automated test.
No. Adding compression is optional in both editions; the skill omits it, which is conservative.
Start with the example and adapt it to your structural system.
New calculation