Design · Timber

Screw tensile design capacity Ftens,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

Design tensile capacity of a timber screw according to EN 1995-1-1 8.7(3): Ftens,Rd = ftens,k / γM2.

Ftens,Rd=ftens,k/γM2\displaystyle F_{tens,\mathrm{Rd}} = f_{tens,k} / \gamma _{\mathrm{M2}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FtensRdftensk

Formula and quantities

SymbolNameUnitNote
ftens,k\displaystyle f_{tens,k}Characteristic tensile screw capacitykN
γM2\displaystyle \gamma_{\mathrm{M2}}Partial factor for fastener steel failure1
Ftens,Rd\displaystyle F_{tens,\mathrm{Rd}}Design tensile screw capacitykNResult

Worked example

ftens,k\displaystyle f_{tens,k} = 18 kN · γM2\displaystyle \gamma_{\mathrm{M2}} = 1.25

Ftens,Rd\displaystyle F_{tens,\mathrm{Rd}} = 14.4 kN

Standard and source

Result
Ftens,Rd\displaystyle F_{tens,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ftens,Rd\displaystyle F_{tens,\mathrm{Rd}} = 14.4 kN= (18 kN) / (1.25 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.