Design · Timber

Design buckling resistance of timber column Nc,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/9/2026

Design flexural buckling load of a timber compression member: Nc,Rd = kc · A · fc,0,d.

Nc,Rd=kc⋅A⋅fc,0,d\displaystyle N_{\mathrm{c},\mathrm{Rd}} = k_{\mathrm{c}} \cdot A \cdot f_{\mathrm{c},0,\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

kcNc,Rd

Formula and quantities

SymbolNameUnitNote
kc\displaystyle k_{\mathrm{c}}Buckling reduction factor–
A\displaystyle ACross-sectional aream²
fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}}Design compressive strength parallel to grainN/mm²
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}}Design buckling resistancekNResult

Worked example

kc\displaystyle k_{\mathrm{c}} = 0.39318 · A\displaystyle A = 0.024 m² · fc,0,d\displaystyle f_{\mathrm{c},0,\mathrm{d}} = 14 N/mm²

Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 132.108 kN · Source: EN 1995-1-1:2004 Eq. (6.23)

Scope and standard

Timber compression members susceptible to flexural buckling according to EN 1995-1-1, clause 6.3.2.

Standard
EN 1995-1-1:2004, clause 6.3.2 (1), Eq. (6.23)
Result
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 132.108 kN= 0.39318 · (0.024 m²) · (14 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.