Design lateral-torsional buckling resistance moment Mb,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/9/2026

Design lateral-torsional buckling resistance moment of a timber beam: Mb,Rd = kcrit · Wy · fm,d.

Mb,Rd=kcrit⋅Wy⋅fm,d\displaystyle M_{\mathrm{b},\mathrm{Rd}} = k_{\text{crit}} \cdot W_{y} \cdot f_{m,\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Mb,Rdkcrit

Formula and quantities

SymbolNameUnitNote
kcrit\displaystyle k_{\text{crit}}Reduction factor for lateral-torsional buckling–
Wy\displaystyle W_{y}Section modulus about major axism³
fm,d\displaystyle f_{m,\mathrm{d}}Design bending strengthN/mm²
Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}}Design lateral-torsional buckling resistance momentNmResult

Worked example

kcrit\displaystyle k_{\text{crit}} = 0.81 · Wy\displaystyle W_{y} = 0.001568 m³ · fm,d\displaystyle f_{m,\mathrm{d}} = 16 N/mm²

Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}} = 20,321.3 Nm · Source: EN 1995-1-1:2004 Eq. (6.33)

Scope and standard

Timber beams subject to lateral-torsional buckling according to EN 1995-1-1, clause 6.3.3.

Standard
EN 1995-1-1:2004, clause 6.3.3 (1), Eq. (6.33)
Result
Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}} in kN*m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Mb,Rd\displaystyle M_{\mathrm{b},\mathrm{Rd}} = 20,321.3 Nm= 0.81 · (0.001568 m³) · (16 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.