Design · Timber
Connection splitting capacity perpendicular to grain F90,Rk
Characteristic splitting capacity for connections loaded perpendicular to grain according to EN 1995-1-1 8.1.4 eq. 8.4: F90,Rk = 14 · b · √(he / (1 - (he / h))).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Member thickness/width | mm | ||
| Loaded edge distance to furthest fastener | mm | ||
| Total member depth | mm | ||
| Characteristic splitting capacity | N | Result |
Worked example
= 140 mm · = 200 mm · = 400 mm
= 39,200 N
Standard and source
- Standard
- EN 1995-1-1:2004
- Result
- in N
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Timber.
Miaknows the formula catalog and asks for what is missing.