Design · Timber
Characteristic nail withdrawal capacity Fax,Rk
Characteristic axial withdrawal capacity of smooth nails according to EN 1995-1-1 8.3.2 eq. 8.23: Fax,Rk = fax,k · d · tpen.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Pointside withdrawal strength parameter | N/m² | ||
| Nail diameter | mm | ||
| Penetration depth of pointside timber | mm | ||
| Axial withdrawal capacity | kN | Result |
Worked example
= 2,500,000 N/m² · = 3.1 mm · = 50 mm
= 0.3875 kN
Standard and source
- Standard
- EN 1995-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.