Design · Timber

Design shear resistance of notched beam VRd

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

Design shear resistance of end-notched timber beams according to EN 1995-1-1 6.5.2 eq. 6.60: VRd = (2 / 3) · kv · b · hef · fv,d.

VRd=(2/3)⋅kv⋅b⋅hef⋅fv,d\displaystyle V_{\mathrm{Rd}} = (2 / 3) \cdot k_{v} \cdot b \cdot h_{\mathrm{ef}} \cdot f_{v,\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

VRdhefkvbfvd

Formula and quantities

SymbolNameUnitNote
kv\displaystyle k_{v}Notch shear reduction factor1
b\displaystyle bBeam widthmm
hef\displaystyle h_{\mathrm{ef}}Effective depth at notchmm
fv,d\displaystyle f_{v,\mathrm{d}}Design shear strengthN/m²
VRd\displaystyle V_{\mathrm{Rd}}Design shear resistancekNResult

Worked example

kv\displaystyle k_{v} = 0.65 · b\displaystyle b = 120 mm · hef\displaystyle h_{\mathrm{ef}} = 180 mm · fv,d\displaystyle f_{v,\mathrm{d}} = 2,000,000 N/m²

VRd\displaystyle V_{\mathrm{Rd}} = 18.72 kN

Standard and source

Result
VRd\displaystyle V_{\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VRd\displaystyle V_{\mathrm{Rd}} = 18.72 kN= (2 / 3) · (0.65 1) · (120 mm) · (180 mm) · (2,000,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.