노치 보의 설계 전단 내력 VRd
EN 1995-1-1 6.5.2 식 6.60에 따른 단부 노치 목재 보의 설계 전단 내력: VRd = (2 / 3) · kv · b · hef · fv,d.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 노치 전단 저감계수 | 1 | ||
| 보의 폭 | mm | ||
| 노치부 유효 깊이 | mm | ||
| 설계 전단강도 | N/m² | ||
| 설계 전단 저항력 | kN | Result |
예제
= 0.65 · = 120 mm · = 180 mm · = 2,000,000 N/m²
= 18.72 kN
Standard and source
- Standard
- EN 1995-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.