Design shear resistance of a rectangular timber beam in fire using the reduced cross-section according to EN 1995-1-2 Clause 4.2.2: VRdfi = (2 / 3) · bef · hef · fvdfi.

VRd,fi=23⋅bef⋅hef⋅fv,d,fi\displaystyle V_{\mathrm{Rd},fi} = \frac{2}{3} \cdot b_{\mathrm{ef}} \cdot h_{\mathrm{ef}} \cdot f_{v,\mathrm{d},fi}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbefhef

Formula and quantities

SymbolNameUnitNote
bef\displaystyle b_{\mathrm{ef}}Effective residual width of timber sectionmm
hef\displaystyle h_{\mathrm{ef}}Effective residual depth of timber sectionmm
fvdfi\displaystyle f_{vdfi}Design shear strength of timber in fireN/m²
VRdfi\displaystyle V_{Rdfi}Design shear resistance in firekNResult

Worked example

bef\displaystyle b_{\mathrm{ef}} = 102 mm · hef\displaystyle h_{\mathrm{ef}} = 351 mm · fvdfi\displaystyle f_{vdfi} = 4,025,000 N/m²

VRdfi\displaystyle V_{Rdfi} = 96.07 kN

Standard and source

Standard
EN 1995-1-2:2004
Result
VRdfi\displaystyle V_{Rdfi} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VRdfi\displaystyle V_{Rdfi} = 96.0687 kN= (2 / 3) · (102 mm) · (351 mm) · (4,025,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.