설계 · 조적

조적벽 설계 전단저항

  • 유형: 저항
  • 버전 1
  • 2026. 11. 13.에 검토됨

무보강 조적벽 압축부 길이에 대한 설계 전단저항: VRd = fvd · t · lc.

VRd=fvd⋅t⋅lc\displaystyle V_{\mathrm{Rd}} = f_{vd} \cdot t \cdot l_{\mathrm{c}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzlct

Formula and quantities

SymbolNameUnitNote
fvd\displaystyle f_{vd}조적조 설계 전단강도N/mm²fvd\displaystyle f_{vd} ≥ 0
t\displaystyle t벽체 두께mmt\displaystyle t > 0
lc\displaystyle l_{\mathrm{c}}벽체 압축부 길이mmlc\displaystyle l_{\mathrm{c}} > 0
VRd\displaystyle V_{\mathrm{Rd}}설계 전단 저항력kNResult

예제

fvd\displaystyle f_{vd} = 0.35 N/mm² · t\displaystyle t = 240 mm · lc\displaystyle l_{\mathrm{c}} = 2,500 mm

VRd\displaystyle V_{\mathrm{Rd}} = 210 kN · Source: 수기 계산

Scope and standard

EN 1996-1-1 조항 6.2에 따른 면내 전단을 받는 무보강 조적벽.

Standard
EN 1996-1-1-2005-a1:2012, 6.2 절, 식 (6.13)
Result
VRd\displaystyle V_{\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VRd\displaystyle V_{\mathrm{Rd}} = 210 kN= (0.35 N/mm²) · (240 mm) · (2,500 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.