設計 · 組積造構造
組積造壁の面外設計曲げ耐力
横荷重を受ける無筋組積造壁の単位幅あたり設計曲げ耐力:MRd = fxd · t² / 6。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 組積造の設計曲げ強度 | N/mm² | ≥ 0 | |
| 壁厚 | mm | > 0 | |
| 単位幅あたり設計曲げ耐力 | N | Result |
例題
= 0.25 N/mm² · = 240 mm
= 2,400 N · Source: 手計算
Scope and standard
EN 1996-1-1 条項 6.3.1.
- Standard
- EN 1996-1-1-2005-a1:2012、6.3.1項、式 (6.15)
- Result
- in kN*m/m
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 組積造構造で開始されます。
Miaknows the formula catalog and asks for what is missing.