Design · Concrete
Concrete one-way shear strength Vc (ACI 318)
Simplified nominal one-way shear strength provided by concrete according to ACI 318-19 Table 22.5.5.1 (SI): Vc = 0.17 · λ · √(fc / MPa) · MPa · bw · d.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Lightweight concrete factor (1.0 normalweight) | 1 | ||
| Specified compressive strength of concrete | N/m² | ||
| Web width | mm | ||
| Effective depth | mm | ||
| Nominal concrete shear strength | kN | Result |
Worked example
= 1 1 · = 28,000,000 N/m² · = 300 mm · = 500 mm
= 134.93 kN
Standard and source
- Standard
- ACI 318-19
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.