Design · Concrete

Effective concrete tension zone depth hc,ef

  • Type: Property
  • Version 1
  • reviewed on 11/10/2026

Effective depth of concrete tension area surrounding reinforcement to EN 1992-1-1 clause 7.3.2 (3).

hc,ef=2.5⋅(h−d)\displaystyle h_{\mathrm{c},\mathrm{ef}} = 2.5 \cdot (h - d)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

hdhc,ef

Formula and quantities

SymbolNameUnitNote
h\displaystyle hOverall section heightmm
d\displaystyle dEffective depthmm
hc,ef\displaystyle h_{\mathrm{c},\mathrm{ef}}Effective tension zone depthmmResult

Worked example

h\displaystyle h = 600 mm · d\displaystyle d = 540 mm

hc,ef\displaystyle h_{\mathrm{c},\mathrm{ef}} = 150 mm · Source: EN 1992-1-1:2004 cl. 7.3.2

Scope and standard

Cracked concrete members to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 7.3.2 (3), Eq. (7.2)
Result
hc,ef\displaystyle h_{\mathrm{c},\mathrm{ef}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
hc,ef\displaystyle h_{\mathrm{c},\mathrm{ef}} = 150 mm= 2.5 · ((600 mm) - (540 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.