Design · Concrete

Effective strength of punching reinforcement fywd,ef

  • Type: Property
  • Version 1
  • reviewed on 11/10/2026

Effective design strength of punching shear reinforcement to EN 1992-1-1 clause 6.4.5 (1).

fywd,ef=250 MPa+0.25⋅d⋅(1 MPa1 mm)\displaystyle f_{ywd,\mathrm{ef}} = 250\,\text{MPa} + 0.25 \cdot d \cdot \left(\frac{1\,\text{MPa}}{1\,\text{mm}}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

d

Formula and quantities

SymbolNameUnitNote
d\displaystyle dEffective depth of slabmm
fywd,ef\displaystyle f_{ywd,\mathrm{ef}}Effective strength of punching reinforcementN/mm²Result

Worked example

d\displaystyle d = 200 mm

fywd,ef\displaystyle f_{ywd,\mathrm{ef}} = 300 N/mm² · Source: EN 1992-1-1:2004 cl. 6.4.5 (1)

Scope and standard

Punching shear reinforcement in slabs to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.4.5 (1), Eq. (6.52)
Result
fywd,ef\displaystyle f_{ywd,\mathrm{ef}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fywd,ef\displaystyle f_{ywd,\mathrm{ef}} = 300 N/mm²= 250 [MPa] + 0.25 · ((200 mm) / 1 [mm]) · 1 [MPa]

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.