Design · Concrete

Minimum flexural reinforcement area (ACI 318)

  • Type: Property
  • Version 1
  • reviewed on 11/15/2026

Minimum area of flexural tension reinforcement (second criterion) according to ACI 318-19 Section 9.6.1.2(b) in SI units: Asmin = (1.4 · MPa · bw · d) / fy.

As,min=1.4⋅bw⋅dfy\displaystyle A_{s,\mathrm{min}} = \frac{1.4 \cdot b_{w} \cdot d}{f_{y}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

dfy

Formula and quantities

SymbolNameUnitNote
bw\displaystyle b_{w}Web widthmm
d\displaystyle dEffective depthmm
fy\displaystyle f_{y}Specified yield strength of reinforcementN/m²
Asmin\displaystyle A_{smin}Minimum flexural reinforcement areamm²Result

Worked example

bw\displaystyle b_{w} = 300 mm · d\displaystyle d = 500 mm · fy\displaystyle f_{y} = 420,000,000 N/m²

Asmin\displaystyle A_{smin} = 500 mm²

Standard and source

Standard
ACI 318-19
Result
Asmin\displaystyle A_{smin} in mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Asmin\displaystyle A_{smin} = 500 mm²= (1.4 · [MPa] · (300 mm) · (500 mm)) / (420,000,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.