Design · Concrete

Effective wall thickness for torsion tef

  • Type: Property
  • Version 1
  • reviewed on 11/10/2026

Effective wall thickness of equivalent thin-walled cross-section for torsion to EN 1992-1-1 clause 6.3.2 (1).

tef=Au\displaystyle t_{\mathrm{ef}} = \frac{A}{u}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

tef

Formula and quantities

SymbolNameUnitNote
A\displaystyle ATotal cross-sectional area enclosed by the outer circumferencemm²
u\displaystyle uOuter circumference of cross-sectionmm
tef\displaystyle t_{\mathrm{ef}}Effective wall thicknessmmResult

Worked example

A\displaystyle A = 150,000 mm² · u\displaystyle u = 1,600 mm

tef\displaystyle t_{\mathrm{ef}} = 93.75 mm · Source: EN 1992-1-1:2004 cl. 6.3.2

Scope and standard

Solid or hollow concrete cross-sections to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.3.2 (1), Eq. (6.27)
Result
tef\displaystyle t_{\mathrm{ef}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
tef\displaystyle t_{\mathrm{ef}} = 93.75 mm= (150,000 mm²) / (1,600 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.