Design · Concrete

Outer control perimeter requiring no reinforcement uout

  • Type: Property
  • Version 1
  • reviewed on 11/10/2026

Perimeter length beyond which shear reinforcement is no longer required to EN 1992-1-1 Eq. (6.54).

uout=β⋅VEdvRd,c⋅d\displaystyle u_{out} = \frac{\beta \cdot V_{\mathrm{Ed}}}{v_{\mathrm{Rd},\mathrm{c}} \cdot d}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

duoutVEd

Formula and quantities

SymbolNameUnitNote
β\displaystyle \betaLoad eccentricity factor–
VEd\displaystyle V_{\mathrm{Ed}}Design punching shear forcekN
vRd,c\displaystyle v_{\mathrm{Rd},\mathrm{c}}Punching shear resistance without reinforcementN/mm²
d\displaystyle dEffective depth of slabmm
uout\displaystyle u_{out}Outer control perimetermmResult

Worked example

β\displaystyle \beta = 1.15 · VEd\displaystyle V_{\mathrm{Ed}} = 600 kN · vRd,c\displaystyle v_{\mathrm{Rd},\mathrm{c}} = 0.6 N/mm² · d\displaystyle d = 200 mm

uout\displaystyle u_{out} = 5,750 mm · Source: EN 1992-1-1:2004 Eq. (6.54)

Scope and standard

Slabs requiring punching shear reinforcement to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.4.5 (4), Eq. (6.54)
Result
uout\displaystyle u_{out} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
uout\displaystyle u_{out} = 5,750 mm= (1.15 · (600 kN)) / ((0.6 N/mm²) · (200 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.