Design · Concrete

Punching shear resistance with reinforcement vRd,cs

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

Design punching shear resistance along the control perimeter with shear reinforcement to EN 1992-1-1 Eq. (6.52).

vRd,cs=0.75⋅vRd,c+1.5⋅dsr⋅Asw⋅fywd,ef⋅1u1⋅d⋅sin⁡α\displaystyle v_{\mathrm{Rd},cs} = 0.75 \cdot v_{\mathrm{Rd},\mathrm{c}} + 1.5 \cdot \frac{d}{s_{r}} \cdot A_{sw} \cdot f_{ywd,\mathrm{ef}} \cdot \frac{1}{u_{1} \cdot d} \cdot \sin \alpha
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

du1vRd,cs

Formula and quantities

SymbolNameUnitNote
vRd,c\displaystyle v_{\mathrm{Rd},\mathrm{c}}Design punching resistance without reinforcementN/mm²
d\displaystyle dEffective slab depthmm
sr\displaystyle s_{r}Radial spacing of perimeter reinforcementmm
Asw\displaystyle A_{sw}Area of one perimeter of shear reinforcementmm²
fywd,ef\displaystyle f_{ywd,\mathrm{ef}}Effective design strength of punching reinforcementN/mm²
u1\displaystyle u_{1}Basic control perimetermm
sin⁡α\displaystyle \sin \alphaSine of angle of shear reinforcement–
vRd,cs\displaystyle v_{\mathrm{Rd},cs}Punching resistance with shear reinforcementN/mm²Result

Worked example

vRd,c\displaystyle v_{\mathrm{Rd},\mathrm{c}} = 0.6 N/mm² · d\displaystyle d = 200 mm · sr\displaystyle s_{r} = 150 mm · Asw\displaystyle A_{sw} = 600 mm² · fywd,ef\displaystyle f_{ywd,\mathrm{ef}} = 300 N/mm² · u1\displaystyle u_{1} = 2,500 mm · sin⁡α\displaystyle \sin \alpha = 1

vRd,cs\displaystyle v_{\mathrm{Rd},cs} = 1.17 N/mm² · Source: EN 1992-1-1:2004 Eq. (6.52)

Scope and standard

Reinforced concrete slabs with punching shear reinforcement to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.4.5 (1), Eq. (6.52)
Result
vRd,cs\displaystyle v_{\mathrm{Rd},cs} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
vRd,cs\displaystyle v_{\mathrm{Rd},cs} = 1.17 N/mm²= 0.75 · (0.6 N/mm²) + 1.5 · ((200 mm) / (150 mm)) · (600 mm²) · (300 N/mm²) · (1 / ((2,500 mm) · (200 mm))) · 1

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.