Design · Concrete

Reduced effective depth by 500°C isotherm method (EN 1992-1-2)

  • Type: Property
  • Version 1
  • reviewed on 11/21/2026

Reduced effective depth dfi of a concrete beam or slab exposed to fire on the compression or tension face according to EN 1992-1-2 Annex B.1: dfi = d - a500.

dfi=d−a500\displaystyle d_{fi} = d - a_{500}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

dfi

Formula and quantities

SymbolNameUnitNote
d\displaystyle dOriginal effective depthmm
a500\displaystyle a_{500}Depth of 500°C isotherm from fire-exposed compression facemm
dfi\displaystyle d_{fi}Reduced effective depth in firemmResult

Worked example

d\displaystyle d = 550 mm · a500\displaystyle a_{500} = 35 mm

dfi\displaystyle d_{fi} = 515 mm

Standard and source

Result
dfi\displaystyle d_{fi} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
dfi\displaystyle d_{fi} = 515 mm= (550 mm) - (35 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.