Design bearing strength on a loaded concrete area A1 (without confinement enhancement) according to ACI 318-19 Section 22.8.3.2: Bd = φ · 0.85 · fc · A1.

ϕBn=ϕ⋅0.85⋅fc′⋅A1\displaystyle \phi B_{n} = \phi \cdot 0.85 \cdot f'_{\mathrm{c}} \cdot A_{1}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fc

Formula and quantities

SymbolNameUnitNote
ϕ\displaystyle \phiStrength reduction factor for bearing (0.65)1
fc\displaystyle f_{\mathrm{c}}Specified compressive strength of concreteN/m²
A1\displaystyle A_{1}Loaded bearing areamm²
Bd\displaystyle B_{\mathrm{d}}Design bearing strengthkNResult

Worked example

ϕ\displaystyle \phi = 0.65 1 · fc\displaystyle f_{\mathrm{c}} = 28,000,000 N/m² · A1\displaystyle A_{1} = 90,000 mm²

Bd\displaystyle B_{\mathrm{d}} = 1,392.3 kN

Standard and source

Standard
ACI 318-19
Result
Bd\displaystyle B_{\mathrm{d}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Bd\displaystyle B_{\mathrm{d}} = 1,392.3 kN= (0.65 1) · 0.85 · (28,000,000 N/m²) · (90,000 mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.