Design · Concrete
Design one-way shear strength (ACI 318)
Total design one-way shear strength combining concrete and stirrup contributions according to ACI 318-19 Section 22.5.1.1: Vd = φ · (Vc + Vs).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Strength reduction factor for shear (0.75) | 1 | ||
| Nominal concrete shear strength | kN | ||
| Nominal stirrup shear strength | kN | ||
| Design shear strength | kN | Result |
Worked example
= 0.75 1 · = 135 kN · = 165 kN
= 225 kN
Standard and source
- Standard
- ACI 318-19
- Result
- in kN