Design · Concrete
Concrete compressive strength reduction factor νprime
Strength reduction factor for cracked concrete in strut-and-tie models to EN 1992-1-1 Eq. (6.57N): nu' = 1 - fck / 250.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Characteristic compressive cylinder strength of concrete | N/m² | ||
| Concrete strength reduction factor for struts | 1 | Result |
Worked example
= 30,000,000 N/m²
= 0.88 1 · Source: EN 1992-1-1:2004 Eq. (6.57N)
Scope and standard
Strut-and-tie design of reinforced concrete members to EN 1992-1-1.
- Standard
- EN 1992-1-1:2004, clause 6.5.2 (2), Eq. (6.57N)
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Which value applies to my case?clarify the boundary conditions
- Limits and special caseswhen the formula does not apply
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.