Design · Composite

Composite beam plastic neutral axis in steel flange xpl (EN 1994-1-1)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Depth of the plastic neutral axis from the top of the concrete slab when located inside the upper steel flange (Ncf < Npl,a) according to EN 1994-1-1 Clause 6.2.1.2: xpl = hc + (Npl,a - Ncf) / (2 · bf · fyd).

xpl=hc+(Npl,a−Ncf)/(2⋅bf⋅fyd)\displaystyle x_{\mathrm{pl}} = h_{\mathrm{c}} + (N_{\mathrm{pl},a} - N_{cf}) / (2 \cdot b_{f} \cdot f_{yd})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

bfhcxpl

Formula and quantities

SymbolNameUnitNote
hc\displaystyle h_{\mathrm{c}}Total depth of concrete slabmm
Npl,a\displaystyle N_{\mathrm{pl},a}Plastic axial resistance of steel sectionkN
Ncf\displaystyle N_{cf}Plastic compressive force of concrete flangekN
bf\displaystyle b_{f}Width of top steel flangemm
fyd\displaystyle f_{yd}Design yield strength of structural steelN/m²
xpl\displaystyle x_{\mathrm{pl}}Plastic neutral axis depthmmResult

Worked examples

IPE 400 with 140 mm slab

hc\displaystyle h_{\mathrm{c}} = 140 mm · Npl,a\displaystyle N_{\mathrm{pl},a} = 3,000 kN · Ncf\displaystyle N_{cf} = 2,600 kN · bf\displaystyle b_{f} = 180 mm · fyd\displaystyle f_{yd} = 355,000,000 N/m²

xpl\displaystyle x_{\mathrm{pl}} = 143.13 mm

HEB 300 with 160 mm slab

hc\displaystyle h_{\mathrm{c}} = 160 mm · Npl,a\displaystyle N_{\mathrm{pl},a} = 4,500 kN · Ncf\displaystyle N_{cf} = 3,800 kN · bf\displaystyle b_{f} = 300 mm · fyd\displaystyle f_{yd} = 355,000,000 N/m²

xpl\displaystyle x_{\mathrm{pl}} = 163.286 mm

Standard and source

Standard
EN 1994-1-1:2004, clause 6.2.1.2
Result
xpl\displaystyle x_{\mathrm{pl}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
xpl\displaystyle x_{\mathrm{pl}} = 143.13 mm= (140 mm) + ((3,000 kN) - (2,600 kN)) / (2 · (180 mm) · (355,000,000 N/m²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.