Design · Composite

Plastic neutral axis depth in concrete flange xpl

  • Type: Property
  • Version 1
  • reviewed on 11/13/2026

Depth of the plastic neutral axis measured from the top of the concrete slab when Npl,a <= Ncf: xpl = Npl,a / (0.85 · fcd · beff).

xpl=Npl,a/(0.85⋅fcd⋅beff)\displaystyle x_{\mathrm{pl}} = N_{\mathrm{pl},a} / (0.85 \cdot f_{cd} \cdot b_{\mathrm{eff}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

beffxpl

Formula and quantities

SymbolNameUnitNote
Npl,a\displaystyle N_{\mathrm{pl},a}Plastic axial resistance of steel sectionkN
fcd\displaystyle f_{cd}Design value of concrete compressive strengthN/m²
beff\displaystyle b_{\mathrm{eff}}Total effective width of concrete flangemm
xpl\displaystyle x_{\mathrm{pl}}Depth of plastic neutral axis in concrete flangemmResult

Worked example

Npl,a\displaystyle N_{\mathrm{pl},a} = 2,580.85 kN · fcd\displaystyle f_{cd} = 20,000,000 N/m² · beff\displaystyle b_{\mathrm{eff}} = 2,000 mm

xpl\displaystyle x_{\mathrm{pl}} = 75.91 mm

Standard and source

Result
xpl\displaystyle x_{\mathrm{pl}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
xpl\displaystyle x_{\mathrm{pl}} = 75.9074 mm= (2,580.85 kN) / (0.85 · (20,000,000 N/m²) · (2,000 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.