Design · Composite
Composite beam transformed second moment of area Ieq (EN 1994-1-1)
Transformed (equivalent steel) second moment of area of an uncracked composite steel-concrete cross-section according to EN 1994-1-1 Clause 5.4.2.2: Ieq = Ia + Ic / n + Aa · Ac · a² / (n · Aa + Ac).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Second moment of area of steel section | cm⁴ | ||
| Second moment of area of effective concrete flange | cm⁴ | ||
| Modular ratio E_a / E_cm (short- or long-term) | 1 | ||
| Cross-sectional area of steel section | cm² | ||
| Cross-sectional area of effective concrete flange | cm² | ||
| Distance between centroids of steel and concrete | cm | ||
| Transformed second moment of area | cm⁴ | Result |
Worked examples
IPE 400 + 14 cm slab
= 23,130 cm⁴ · = 45,733 cm⁴ · = 6.5 · = 84.5 cm² · = 2,800 cm² · = 27 cm
= 81,664.4 cm⁴
Long-term creep n=15
= 23,130 cm⁴ · = 45,733 cm⁴ · = 15 · = 84.5 cm² · = 2,800 cm² · = 27 cm
= 68,583.6 cm⁴
Standard and source
- Standard
- EN 1994-1-1:2004, clause 5.4.2.2
- Result
- in cm⁴
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Composite.
Miaknows the formula catalog and asks for what is missing.