Design · Composite

Steel contribution ratio δ

  • Type: Property
  • Version 1
  • reviewed on 11/13/2026

Ratio of structural steel plastic resistance to total plastic resistance of a composite column (simplified method requires 0.2 <= delta <= 0.9): δ = (Aa · fyd) / Npl,Rd.

δ=(Aa⋅fyd)/Npl,Rd\displaystyle \delta = (A_{a} \cdot f_{yd}) / N_{\mathrm{pl},\mathrm{Rd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

δNplRd

Formula and quantities

SymbolNameUnitNote
Aa\displaystyle A_{a}Cross-sectional area of structural steel sectioncm²
fyd\displaystyle f_{yd}Design yield strength of structural steelN/m²
Npl,Rd\displaystyle N_{\mathrm{pl},\mathrm{Rd}}Design plastic resistance of composite columnkN
δ\displaystyle \deltaSteel contribution ratio1Result

Worked example

Aa\displaystyle A_{a} = 118.4 cm² · fyd\displaystyle f_{yd} = 355,000,000 N/m² · Npl,Rd\displaystyle N_{\mathrm{pl},\mathrm{Rd}} = 7,247.3 kN

δ\displaystyle \delta = 0.58

Standard and source

Result
δ\displaystyle \delta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
δ\displaystyle \delta = 0.579968 1= ((118.4 cm²) · (355,000,000 N/m²)) / (7,247.3 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.