Privacy settings

We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000077 · Skill

EN 1992-1-1:2004+AC:2010, 3.1 Table 3.1, 6.2.2(6), 6.2.5DIN EN 1992-1-1/NA:2013-04 (content per Synopse 2010-02) + NA/A1:2015-12, NDP zu 3.1.6(1)P and (2)P, NDP zu 6.2.2(6), NCI zu 6.2.5(1) to (5)NABau Auslegung Nr. 2 (2019) to NCI zu 6.2.5(5)

Shear at the interface between concrete cast at different times to Eurocode 2

Enter the shear force, the joint width, the lever arm or effective depth, the concrete, the joint surface, and the joint reinforcement. Mia checks the joint to EN 1992-1-1, 6.2.5, with the CEN recommended values or the German National Annex, and shows adhesion, friction, reinforcement, and upper limit with their clauses.

Mia

Mia guides you step by stepShe guides you through the inputs and explains the results.

Worked example

Composite beam · rough joint · German NA

Interface shear fulfilled
Composite beam · rough joint · German NA
Load
VEd = 115 kN · β = 1.0
Joint
bi = 300 mm · rough · as = 500 mm²/m
Section
d = 500 mm · z = 0.9·d · C30/37
Code
EN 1992-1-1, German National Annex

Check the interface shear to EN 1992-1-1:2004+AC:2010 with DIN EN 1992-1-1/NA:2013-04 + NA/A1:2015-12. Precast beam with cast-in-place topping, VEd = 115 kN, β = 1.0, joint width bi = 300 mm, effective depth d = 500 mm, C30/37, rough joint, joint reinforcement as = 500 mm²/m at 90°, B500, σn = 0, static loading.

Key results

Shear stress vEdi
0.852 N/mm²
Resistance vRdi
1.068 N/mm² (η = 0.80)
Upper limit vRdi,max
4.25 N/mm² (η = 0.20)

Deterministic values of the calculation core for the stated inputs; z = 0.9·d = 450 mm calculated, reinforcement term raised to 1.2·μ (NCI zu 6.2.5(1)).

  • — The whole compression zone lies in the topping (β = 1.0).
  • — fctd = 0.85·fctk,0.05 / 1.5 with fctk,0.05 from Table 3.1.

Required inputs

  • Code: EN 1992-1-1:2004+AC:2010 with the CEN recommended values or the German National Annex
  • Design shear force VEd and the force ratio β
  • Joint width bi and effective depth d (z = 0.9·d) or lever arm z
  • Strength of the weaker concrete fck and of the joint reinforcement fyk
  • Joint surface, joint reinforcement as with its angle α, normal stress σn

What you receive

  • Governing check and utilization
  • Shear stress vEdi and resistance vRdi
  • Upper limit vRdi,max
  • Required joint reinforcement as,req
  • Calculation table with formula, value, unit, and clause
  • Notes on fatigue, very smooth joints, and excluded cases

Start from an input template

These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.

Prepare your calculation
Dlubal CALC
Interface shear | EC 2
Structural calculation to standard

System sketch

All required fields completed

Inputs completeReady to calculate

What this skill checks

Joint shear resistance

Adhesion c·f_ctd, friction μ·σ_n, and the joint reinforcement ρ·f_yd·(μ·sin α + cos α) to Eq. (6.25), with the German NA raise to 1.2·μ.

Upper limit

The upper limit 0.5·ν·f_cd, with ν from Eq. (6.6N) or from the joint surface under the German NA.

Required joint reinforcement

The joint reinforcement a_s in mm²/m that the resistance check requires.

Ready for your first check?

Start with the example and adapt it to your structural system.

New calculation