Privacy settings

We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000155 · Skill

ANSI/AWC NDS-2024NDS Supplement 2024ASCE/SEI 7-22

Design a timber column or stud to NDS 2024

Describe the height, end conditions, bracing, the member (sawn lumber or glulam) and the axial and wind loads. Mia applies the NDS adjustment factors, checks compression with column stability, combined bending and compression, shear, bearing and wind deflection in ASD or LRFD, and names the governing check.

Mia

Mia guides you step by stepShe guides you through the inputs and explains the results.

Worked example

2x4 DF-L No.2 studs · 16 in. o.c. · 10 ft · 300 lb D + 900 lb S · 25 psf wind · ASD

Design verified: bending and compression (NDS 3.9.2) governs
System
Stud, pinned-pinned, 10 ft, weak axis sheathed
Member
2x4 Douglas Fir-Larch No.2, repetitive (Cr = 1.15)
Loads
PD = 300 lb, PS = 900 lb, wind 25 psf at 16 in. o.c.
Standard
NDS 2024 ASD, ASCE/SEI 7-22

Check 2x4 Douglas Fir-Larch No.2 wall studs at 16 in. on center, 10 ft high, pinned at both ends and sheathed, with 300 lb dead and 900 lb snow per stud and 25 psf wind on the wall, to NDS 2024 ASD with an H/180 wind deflection limit.

Key results

Combined, D + 0.75(0.6W) + 0.75(0.7S)
0.61 (fc = 147 psi, fb1 = 735 psi, F'_b1 = 2484 psi, FcE1 = 406 psi)
Compression, D + 0.7S
fc = 177 psi <= F'_c = 384 psi (CP = 0.215, le/d = 34.3), 0.46
Wind deflection
0.367 in <= 0.667 in (H/180), 0.55
Bearing on the plate
177 psi <= 781 psi (Cb = 1.25), 0.23

All values are deterministic for the stated inputs and reproduced by the skill's calculation code with the 2024 NDS Supplement Table 4A values for Douglas Fir-Larch No.2 (Fb = 900 psi, Fc = 1350 psi, Fc⊥ = 625 psi, Emin = 580 000 psi).

  • — The sheathing braces the weak axis, so the stud buckles about its strong axis only (le/d = 120/3.5 = 34.3).
  • — CF = 1.15 on Fc and 1.5 on Fb for a 4 in. wide member; Cr = 1.15 on Fb.
  • — Every ASCE 7-22 ASD combination is checked with the CD of its shortest load; with wind CD = 1.6.
  • — Wind deflection with 0.42 x the wind load (IBC Table 1604.3, footnote f).
  • — Self-weight of the stud is ignored.

Required inputs

  • Height and end conditions
  • Bracing of the weak axis
  • Member, species and grade, or glulam combination and size
  • Axial loads D, L, Lr, S, W
  • Lateral wind and spacing, or eccentricity, if any

What you receive

  • Governing check, combination and utilization
  • le/d, FcE, CP and F'_c with every factor
  • Combined check per NDS 3.9.2 / 15.4.1
  • Bearing on the plate and end-grain bearing
  • Wind deflection against the IBC limit

Start from an input template

These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.

Prepare your calculation
Dlubal CALC
Configure your timber column
Structural calculation to standard

System sketch

L = 10 ftNEd = 0.300008 kip

ft
ft
All required fields completed

Inputs completeReady to calculate

What this skill checks

Column stability C_P

Slenderness about both axes with K_e from Appendix G, F_cE and C_P per NDS 3.7 with c = 0.8 for sawn lumber and 0.9 for glulam.

Wind and eccentricity

Combined bending and compression per NDS 3.9.2 and 15.4 with C_L and the amplification 1 - f_c/F_cE1, for wall studs and eccentric column loads.

Bearing at the ends

Bearing of the stud on the plate with the bearing area factor C_b, and end-grain bearing against F_c*.

ASD and LRFD with ASCE 7-22

All combinations of D, L, Lr, S and W, each with its load duration factor or time effect factor, and the governing one named.

Ready for your first check?

Start with the example and adapt it to your structural system.

New calculation