Complete DDMaS parameter set
Derives strengths, moduli, Poisson's ratio, plastic strain, fracture energies and the Rankine-Hill parameters α, β and γ for the orthotropic plastic masonry model.
Privacy settings
We use Microsoft Clarity to understand how CALC is used — only if you agree. Necessary cookies keep the app working (sign-in, security, free-quota enforcement) and are always active.

SKL-000114 · Skill
EN 1996-1-1ÖNORM B 1996-1-1prEN 1996-1-1:2019Describe the masonry of an existing wall to Mia in your own words. Unit dimensions, unit and mortar strength and the initial shear strength are enough to start. She derives the complete parameter set of the orthotropic plastic masonry model in RFEM after the DDMaS method, as characteristic, ULS/SLS or seismic values, shows the calculation path and, on your confirmation, creates the material directly in your open RFEM model and reads every value back.
Mia guides you step by stepShe guides you through the inputs and explains the results.
Existing masonry of solid clay bricks, unit group 1, unit height 65 mm, unit length in wall view 140 mm, fb = 27 N/mm², normal mortar fm = 5 N/mm², single-leaf, head joints filled, fvk0 = 0.2 N/mm², specific weight 18 kN/m³. Derive the ULS/SLS material with γM = 2.5 for RFEM.
These templates prefill the form with typical inputs. They are not calculated results; the calculation runs in CALC.
Derives strengths, moduli, Poisson's ratio, plastic strain, fracture energies and the Rankine-Hill parameters α, β and γ for the orthotropic plastic masonry model.
Characteristic values, ULS/SLS design values divided by γ_M, or seismic values from mean strengths divided by γ_M,seis = max(1.5; 2/3·γ_M) to EN 1998-1.
Clay, lightweight concrete and AAC units in groups 1S to 4 and the old Austrian format, normal, thin-bed and lightweight mortar, filled or unfilled head joints, longitudinal joint.
On your confirmation, Mia creates the material in the active RFEM model with the Masonry Design add-on, without overwriting existing materials, and compares every value read back.
Normative basis
Frequently asked questions
Unit material and group, unit height and length in wall view, normalized unit compressive strength fb, mortar type and strength fm, the initial shear strength fvk0 to EN 1996-1-1, the head joints, the bond and the value set. γM = 2.5 and a specific weight of 18 kN/m³ are offered as proposals.
Characteristic values, ULS/SLS design values with strengths divided by γM and characteristic stiffness, and seismic values from mean strengths (fk/0.85) divided by γM,seis = max(1.5; 2/3·γM) to EN 1998-1. Each set is calculated anew, because the fracture energies do not scale with the factor.
The parallel compressive strength is reduced to 0.35 · fk,∥, the initial shear strength is halved and the limit shear stress uses 0.045 · fb. The parallel tensile strength then equals the halved initial shear strength, as in the DDMaS method.
Only after your explicit Yes. Mia writes to the active model with the next free material number, never overwrites or deletes a material, and switches the Masonry Design add-on on only in an empty model. In an existing model she asks you to switch it on.
Start with the example and adapt it to your structural system.
New calculation