Design · Steel
Fire design moment resistance of Class 1/2 steel beam (EN 1993-1-2)
Design bending moment resistance of a Class 1 or Class 2 steel beam in fire according to EN 1993-1-2 Clause 4.2.3.3 Eq. (4.10)/(4.11): MfitRd = (ky · Wpl · fy) / (γMfi · κ1 · κ2).
- EN 1993-1-2:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Reduction factor for yield strength at steel temperature | 1 | ||
| Plastic section modulus | mm³ | ||
| Yield strength of steel at 20°C | N/m² | ||
| Partial factor for steel in fire (typically 1.0) | 1 | ||
| Adaptation factor for non-uniform temperature across section | 1 | ||
| Adaptation factor for non-uniform temperature along beam | 1 | ||
| Design bending moment resistance in fire | kNm | Result |
Worked example
= 0.78 1 · = 628,400 mm³ · = 355,000,000 N/m² · = 1 1 · = 0.7 1 · = 1 1
= 248.58 kNm
Standard and source
- Standard
- EN 1993-1-2:2005
- Result
- in kNm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Steel.
Miaknows the formula catalog and asks for what is missing.