设计 · 钢

1/2 类钢梁火灾下抗弯设计承载力 (EN 1993-1-2)

  • 类型:承载力
  • 版本1
  • 2026/11/21已审核

根据 EN 1993-1-2 第 4.2.3.3 条式 (4.10)/(4.11) 的 1 类或 2 类钢梁火灾下抗弯设计承载力:MfitRd = (ky · Wpl · fy) / (γMfi · κ1 · κ2)。

Mfi,t,Rd=ky,Θ⋅Wpl⋅fyγM,fi⋅κ1⋅κ2\displaystyle M_{fi,t,\mathrm{Rd}} = \frac{k_{y,\Theta} \cdot W_{\mathrm{pl}} \cdot f_{y}}{\gamma_{M,fi} \cdot \kappa_{1} \cdot \kappa_{2}}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
ky\displaystyle k_{y}钢材温度下屈服强度折减系数1
Wpl\displaystyle W_{\mathrm{pl}}塑性截面模数mm³
fy\displaystyle f_{y}20°C 时钢材屈服强度N/m²
γMfi\displaystyle \gamma_{Mfi}火灾下钢材分项系数(通常取 1.0)1
κ1\displaystyle \kappa_{1}截面非均匀温度调整系数1
κ2\displaystyle \kappa_{2}梁纵向非均匀温度调整系数1
MfitRd\displaystyle M_{fitRd}火灾下抗弯设计承载力kNmResult

实例

ky\displaystyle k_{y} = 0.78 1 · Wpl\displaystyle W_{\mathrm{pl}} = 628,400 mm³ · fy\displaystyle f_{y} = 355,000,000 N/m² · γMfi\displaystyle \gamma_{Mfi} = 1 1 · κ1\displaystyle \kappa_{1} = 0.7 1 · κ2\displaystyle \kappa_{2} = 1 1

MfitRd\displaystyle M_{fitRd} = 248.58 kNm

Standard and source

Standard
EN 1993-1-2:2005
Result
MfitRd\displaystyle M_{fitRd} in kNm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
MfitRd\displaystyle M_{fitRd} = 248.577 kNm= ((0.78 1) · (628,400 mm³) · (355,000,000 N/m²)) / ((1 1) · (0.7 1) · (1 1))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 钢 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.