Column web panel design shear resistance Vwp,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

Plastic design shear resistance of an unstiffened column web panel according to EN 1993-1-8 6.2.6.1 eq. 6.1: Vwp,Rd = 0.9 · fy,wc · Avc / (√(3) · γM0).

Vwp,Rd=0.9⋅fy,wc⋅Avc/(3⋅γM0)\displaystyle V_{wp,\mathrm{Rd}} = 0.9 \cdot f_{y,wc} \cdot A_{vc} / (\sqrt{3} \cdot \gamma _{\mathrm{M0}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
fy,wc\displaystyle f_{y,wc}Column web yield strengthN/m²
Avc\displaystyle A_{vc}Column shear areamm²
γM0\displaystyle \gamma_{\mathrm{M0}}Partial factor gamma_M01
Vwp,Rd\displaystyle V_{wp,\mathrm{Rd}}Column web panel shear resistancekNResult

Worked example

fy,wc\displaystyle f_{y,wc} = 355,000,000 N/m² · Avc\displaystyle A_{vc} = 2,500 mm² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

Vwp,Rd\displaystyle V_{wp,\mathrm{Rd}} = 461.16 kN

Standard and source

Result
Vwp,Rd\displaystyle V_{wp,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Vwp,Rd\displaystyle V_{wp,\mathrm{Rd}} = 461.159 kN= 0.9 · (355,000,000 N/m²) · (2,500 mm²) / (sqrt(3) · (1 1))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.