Design · Steel

Fire design shear resistance of steel member (EN 1993-1-2)

  • Type: Resistance
  • Version 1
  • reviewed on 11/21/2026

Design shear resistance of a steel cross-section at elevated temperature according to EN 1993-1-2 Clause 4.2.3.3 Eq. (4.16): VfitRd = (ky · Av · fy) / (√(3) · γMfi).

Vfi,t,Rd=ky,Θ⋅Av⋅fy3⋅γM,fi\displaystyle V_{fi,t,\mathrm{Rd}} = \frac{k_{y,\Theta} \cdot A_{v} \cdot f_{y}}{\sqrt{3} \cdot \gamma_{M,fi}}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
ky\displaystyle k_{y}Reduction factor for yield strength at web temperature1
Av\displaystyle A_{v}Shear area of steel cross-sectionmm²
fy\displaystyle f_{y}Yield strength of steel at 20°CN/m²
γMfi\displaystyle \gamma_{Mfi}Partial factor for steel in fire (typically 1.0)1
VfitRd\displaystyle V_{fitRd}Design shear resistance in firekNResult

Worked example

ky\displaystyle k_{y} = 0.78 1 · Av\displaystyle A_{v} = 2,568 mm² · fy\displaystyle f_{y} = 355,000,000 N/m² · γMfi\displaystyle \gamma_{Mfi} = 1 1

VfitRd\displaystyle V_{fitRd} = 410.54 kN

Standard and source

Standard
EN 1993-1-2:2005
Result
VfitRd\displaystyle V_{fitRd} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VfitRd\displaystyle V_{fitRd} = 410.542 kN= ((0.78 1) · (2,568 mm²) · (355,000,000 N/m²)) / (sqrt(3) · (1 1))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.