Design · Connections

Fillet weld resistance per unit length Fw,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Design resistance per unit length of a steel fillet weld: Fw,Rd = fvw,d · a.

Fw,Rd=fvw,d⋅a\displaystyle F_{w,\mathrm{Rd}} = f_{vw,\mathrm{d}} \cdot a
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

a

Formula and quantities

SymbolNameUnitNote
fvw,d\displaystyle f_{vw,\mathrm{d}}Design shear strength of fillet weldN/m²
a\displaystyle aEffective throat thickness of fillet weldmm
Fw,Rd\displaystyle F_{w,\mathrm{Rd}}Design weld resistance per unit lengthkN/mResult

Worked example

fvw,d\displaystyle f_{vw,\mathrm{d}} = 261,730,000 N/m² · a\displaystyle a = 5 mm

Fw,Rd\displaystyle F_{w,\mathrm{Rd}} = 1,308.65 kN/m

Standard and source

Result
Fw,Rd\displaystyle F_{w,\mathrm{Rd}} in kN/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fw,Rd\displaystyle F_{w,\mathrm{Rd}} = 1,308.65 kN/m= (261,730,000 N/m²) · (5 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.